{"product_id":"can-fd-eth-rs232-rs485-converter","title":"CAN FD ETH RS232\/RS485 Converter","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe CAN FD ETH RS232\/RS485 Converter is a DIN-rail CAN FD to Ethernet\/RS232\/RS485 bidirectional converter, featuring high-speed, low-latency, stable performance, ease of use, and cost-effectiveness. It supports five data conversion modes: transparent conversion, transparent conversion with ID, standard protocol conversion, Modbus protocol conversion, and custom protocol conversion. Enables interconnection between CAN and Network port \/ serial port devices, compatible with CAN FD and CAN 2.0A\/2.0B protocols.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIt features industrial-grade design, supports -40°C ~ 85°C stable working, 9V ~ 36V wide power input, 5Kbps~1Mbps CAN FD arbitration domain baud rate, and 100Kbps~5Mbps CAN FD data domain baud rate.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIt supports parameter configuration via host computer, built-in 120Ω terminal resistors (switchable via DIP switches), supports DIN-rail mounting, easy to configure and install.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0668\/0641\/5437\/files\/E21001-show1.jpg?v=1788086551\" alt=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0668\/0641\/5437\/files\/E21001-show2.jpg?v=1788086551\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecification\u003c\/h2\u003e\n\u003ctable class=\"wikitable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking voltage\u003c\/td\u003e\n\u003ctd\u003eDC 9V ~ 36V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e110 × 27 × 85.6 (mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eDIN-rail installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReload button\u003c\/td\u003e\n\u003ctd\u003eLong press to restore factory settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicator light\u003c\/td\u003e\n\u003ctd\u003ePOWER, WORK, COM, CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"wikitable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAN port specification\u003c\/td\u003e\n\u003ctd\u003e1-ch CAN port, supports CAN FD, compatible with CAN 2.0A\/2.0B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAN port baud rate\u003c\/td\u003e\n\u003ctd\u003eArbitration domain baud rate: 5Kbps ~ 1Mbps\u003cbr\u003eData domain baud rate: 100Kbps ~ 5Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal resistor\u003c\/td\u003e\n\u003ctd\u003eBuilt-in 2 × 120Ω terminal resistors\u003cbr\u003e\n\u003cp\u003eSwitching either DIP switch to ON connects one 120 Ω resistor in parallel\u003cbr\u003eSwitching both to ON connects two 120Ω resistors in parallel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork port specification\u003c\/td\u003e\n\u003ctd\u003eRJ45, 10\/100Mbps, cross-connection adaptive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial port specification\u003c\/td\u003e\n\u003ctd\u003eSupports 1-ch RS485 or RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"wikitable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking temperature\u003c\/td\u003e\n\u003ctd\u003e-40℃ ~ 85℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40℃ ~ 105℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking humidity\u003c\/td\u003e\n\u003ctd\u003e5% ～ 95% RH (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage humidity\u003c\/td\u003e\n\u003ctd\u003e5% ～ 95% RH (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"wikitable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetworking protocol\u003c\/td\u003e\n\u003ctd\u003eTCP server, TCP client, UDP server, UDP client (only network port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus gateway\u003c\/td\u003e\n\u003ctd\u003eNetwork port: CAN FD to Modbus TCP (Master\/Slave)\u003cbr\u003e\n\u003cp\u003eSerial port: CAN FD To Modbus RTU (Master\/Slave)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSend message\u003c\/td\u003e\n\u003ctd\u003eSupports configuring up to 64 transmission messages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceive message\u003c\/td\u003e\n\u003ctd\u003eSupports configuring up to 64 receiving messages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol conversion\u003c\/td\u003e\n\u003ctd\u003eTransparent conversion, transparent conversion with ID, standard protocol conversion, Modbus protocol conversion, and custom protocol conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAN ID\u003c\/td\u003e\n\u003ctd\u003eSupports standard frame and extended frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame ID filtering\u003c\/td\u003e\n\u003ctd\u003eSupports only standard frames, only extended frames, and custom input frame ID (up to 32 groups)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack frame time\u003c\/td\u003e\n\u003ctd\u003eSupports customizing the number of frames and the time of frame packing (Network port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChange direction\u003c\/td\u003e\n\u003ctd\u003eSupports bidirectional conversion, only serial \/ network port to CAN, and only CAN to serial \/ network port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware upgrade\u003c\/td\u003e\n\u003ctd\u003eSupports the host computer for firmware upgrade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter configuration\u003c\/td\u003e\n\u003ctd\u003eAT command and host computer software configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther features\u003c\/td\u003e\n\u003ctd\u003eSupports heartbeat packets; register packets; normal, loopback, and only listen modes (Network port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"wikitable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eESD protection\u003c\/td\u003e\n\u003ctd\u003eAir discharge: 8 KV, Contact discharge: 6 KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEft\/Burst\u003c\/td\u003e\n\u003ctd\u003ePower circuit: 2KV; RS485\/RS232 circuit: 1KV; Network port \u0026amp; CAN port circuit: 1KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge immunity test\u003c\/td\u003e\n\u003ctd\u003ePower circuit: 1kV differential mode, 2kV common mode;\u003cbr\u003eCAN circuit: 2KV common mode;\u003cbr\u003eSerial port \u0026amp; Network port circuit: 2kV common mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eIndicator Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable border=\"1;\"\u003e\n\u003ctbody\u003e\n\u003ctr align=\"center\"\u003e\n\u003ctd\u003eIndicator\u003c\/td\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eFunction description\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"center\"\u003e\n\u003ctd\u003ePOWER light\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003eAlways on when powered on, turns off when powered off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"center\"\u003e\n\u003ctd\u003eSTA light\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003ctd\u003eFlickering: Device operating normally, frequency 1s;\n\u003cp\u003eStrobe: Enters the CAN bus passive error state; Always on: CAN bus running abnormally\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"center\"\u003e\n\u003ctd\u003eNET light\u003c\/td\u003e\n\u003ctd\u003eGreen\/Red\u003c\/td\u003e\n\u003ctd\u003eGreen flickering: Indicates that the network port is receiving data\n\u003cp\u003eRed flickering: Indicates that data is being sent from the network port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"center\"\u003e\n\u003ctd\u003eCAN light\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003eGreen flickering: Indicates that the CAN port is receiving data\n\u003cp\u003eRed flickering: Indicates that data is being sent from the CAN port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSoftware\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noreferrer noopener\" class=\"external text\" href=\"https:\/\/files.waveshare.com\/wiki\/CAN-FD-ETH-RS232-RS485-Converter\/tool\/WS-CAN-FD-Converter_v1.3.9.0.exe\" target=\"_blank\"\u003eConfiguration software WS-CAN-FD-Converter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"nofollow noreferrer noopener\" class=\"external text\" href=\"https:\/\/files.waveshare.com\/wiki\/common\/Sscom5.13.1.zip\" target=\"_blank\"\u003eSscom software\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"WaveShare","offers":[{"title":"Default Title","offer_id":43659362992205,"sku":"E21001-001","price":106.44,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0668\/0641\/5437\/files\/E21001-win1.jpg?v=1788086750","url":"https:\/\/www.mlab.com.au\/products\/can-fd-eth-rs232-rs485-converter","provider":"MLAB","version":"1.0","type":"link"}